Hopewell Csa-Hl1
Key Takeaway
Hopewell Csa-Hl1 is classified as significant hazard in Florida. It was completed in 1982 and is 44 years old. Its primary use is tailings. Significant hazard means failure could cause economic or environmental damage. Learn more.
Physical Details
| Dam Height | 35 ft (taller than 75.5% in FL) |
| Dam Length | 16,275 ft |
| Dam Type | Earth |
| Max Storage | 12.5K acre-ft |
| Normal Storage | 11.6K acre-ft |
| Surface Area | 388 acres |
| Drainage Area | 1 sq mi |
| Max Discharge | 160 cfs |
| Year Completed | 1982 (44 years old) |
| Year Modified | 1984 |
| NID ID | FL11010 |
Safety Information
No probable loss of human life, but can cause economic loss, environmental damage, or disruption of lifeline facilities.
Hazard potential describes downstream consequences of failure, not the dam's current condition. What does this mean?
Ownership
THE MOSAIC COMPANY
Private
Nearby Dams
Hil10
Hillsborough, FL
Unknown 14 ftHl2
Hillsborough, FL
Significant Hazard 6 ftHopewell Csa-Hl-4
Hillsborough, FL
Significant Hazard 37 ftHopewell Csa Hl3
Hillsborough, FL
Significant Hazard 32 ftEdward Medard Reservoir Dam
Hillsborough, FL
High Hazard 40 ftHil12
Hillsborough, FL
Unknown 32 ftSouth Hopewell Eleanor Area
Hillsborough, FL
Low Hazard 20 ftPol52
Polk, FL
Unknown 20 ftFrequently Asked Questions
What is the hazard classification of Hopewell Csa-Hl1?
Hopewell Csa-Hl1 is classified as Significant Hazard. No probable loss of human life, but can cause economic loss, environmental damage, or disruption of lifeline facilities. This classification refers to the potential downstream consequences of a failure, not the dam's current structural condition.
Who owns and operates Hopewell Csa-Hl1?
Hopewell Csa-Hl1 is owned by THE MOSAIC COMPANY (Private). The owner is responsible for maintenance, inspections, and compliance with dam safety regulations.
When was Hopewell Csa-Hl1 built?
Hopewell Csa-Hl1 was completed in 1982, making it 44 years old. Many U.S. dams were built between the 1930s and 1970s during a period of major infrastructure investment.
What is the primary purpose of Hopewell Csa-Hl1?
Hopewell Csa-Hl1 serves the following purposes: Tailings. Many dams in the U.S. are multi-purpose, supporting flood control, water supply, recreation, and other uses.
How tall is Hopewell Csa-Hl1?
Hopewell Csa-Hl1 has a dam height of 35 ft. Dam height is measured from the natural streambed at the downstream toe to the top of the dam, and may differ from the visible height.
When was Hopewell Csa-Hl1 last inspected?
Hopewell Csa-Hl1 was last inspected on July 20, 2005. Inspection dates indicate when a formal review occurred, not the results of that inspection.